Specifications:-
Warranty of Flooring Radient Panel Test Machine: 1 year, 1 Year
Certification: CSA, pock, Reach, IECEE, sock, UL, EPA, GS
Customized support: OEM, ODM
Model Number:D248
Power: Electronic
Application: Floor Coverings Material
Power supply: 220V 50Hz
Standard: ISO9239
Smoke exhausting speed 🙁 2.5±0.2) m/s
Material: SUS 304 Stainless Steel
Total power: 2 KW
Burning chamber size: L1420 * W1200 * H2300mm
Size: L2530 * W1270 * H2700 mm
Main technical parameters | |
Timer | Accuracy error < 1s/h |
Heat flux meter measurement range | (0 ~ 15) KW/m2 |
Heat flux meter accuracy | ±0.2 KW/m2 |
Heat flux meter precision | ±3% |
Thermal radiation high temperature measurement range | 480 ~ 530℃, accuracy is ±0.5℃ |
Black body temperature error | ±5℃ |
Smoke exhausting speed | (2.5±0.2) m/s |
Smoke exhausting capacity | (39-85) m3/min |
Porous refractory radiant panel size | 300mm x 450mm, can withstand high temperatures of about 900℃ |
Thermocouple | K-type stainless steel armored thermocouple with a diameter of 3.2 mm |
Igniter | Outer diameter Ф10mm inner diameter Ф6mm, 35 Ф0.7mm radial holes on the torch |
Ignition flame height | Adjustable from 60 to 120 mm |
Burning chamber size | L1420 x W1200 x H2300 mm |
Working power | AC220V, 50HZ; total power is 2KW |
Dimensions | L2530 x W1270 x H2700 mm (including electrical control cabinet size). |
Frequently Asked Questions:-
What is ISO 9239 Radiant Heat Source Fire Test Machine?
Flooring Radient Panel Test Machine specifies a method for assessing the wind-opposed burning behaviour and spread of flame of horizontally mounted floorings exposed to a heat flux radiant gradient in a test chamber, when ignited with pilot flames. This method is applicable to all types of flooring.