DIN 53436 Noxious Gas Tester Flammability Analyzer

Availability:

<p class="stock in-stock"></p>


Noxious Gas Tester Flammability Analyzer is designed and manufactured in accordance with the standard requirements of GB/T20285-2006 “Material Toxicity Hazard Classification of Materials”.

(max file size 512 MB)

DIN 53436 Noxious Gas Tester Flammability Analyzer

Specifications:-

Warranty:-1 year, 1 Year

Certification:-CSA, pock, Reach, IECEE, sock, UL, EPA, GS

Control accuracy:-Static ±1℃

Model Number:-D325

Power:-Electronic

Customized support:-OEM, ODM

Temperature control range:-300℃ ~ 1000℃

Application:-Wire & Cable Test

Material:-SUS 304 Stainless Steel

Maximum power:-2 KW

Test chamber size:-L2400 * W680 * H1730 mm

Standard:-DIN 53436

Air flow:-0~25L/min adjustable

Power supply voltage:-AC220V±10%, 50HZ

 Main technical parameters
Power supply AC220V±10%, 50HZ, current ≤ 10A
Maximum power 2 KW
Maximum heating power 1200 W
Temperature control range 300℃ ~ 1000℃
Control accuracy Static ±1℃
Air flow 0~25 L/min adjustable
Ring furnace displacement rate (10±0.1) mm/min
Air source Dry, clean compressed air, 2-8 kg/cm2
Microcomputer control Computer operation
Ring furnace heating temperature calibration Display time, and actual temperature measured temperature curve comparison chart.
Graph Showing of the squirrel cage the angular velocity in real time
Maximum stroke of the ring furnace > 600 mm
Function With manual, automatic ring furnace fast forward and retreat function
Test chamber size L2400 x W680 x H1730 mm
Equipment weight 425 KGS

Precautions

The equipment should be placed on ground, not inclined, and the horizontal and stable environment should be clean.

This equipment public places or near flammable, explosive should not be placed in and corrosive chemicals, so equipment or personal injury as to avoid damage to the caused by fire.

A single phase be provided at the equipment220 V AC power supply must location for use.

During the use should be reliably grounded of the equipment, it to avoid electric shock.

During the test, the test chamber shall be closed.

It is not suitable to or plug in avoid data loss caused by removable device in the computer used for supporting install other equipment software the equipment, so as to computer poisoning and unnecessary trouble.

Equipment wear protective clothing when operators or managers must testing equipment, so as by materials and harm to avoid toxic smoke generated human health.

The door tube and quartz boat are all they should be treated made of the test chamber, quartz glass of glass, which are easy to be broken, so with care.

Frequently Asked Questions:-

What is DIN 53436?

It means producing from materials in an airstream thermal decomposition products and their toxicological testing; determination of decomposition apparatus and test-temperature.

What is Noxious Gas?

A noxious gas very harmful Many household or substance is poisonous or products give off noxious fumes.

What is the difference between obnoxious and noxious?

As adjectives and obnoxious Is that noxious is harmful; injurious the difference between noxious while obnoxious is, very annoying, odious or extremely unpleasant, offensive contemptible.

 

DIN 53436 Noxious Gas Tester Flammability Analyzer