Cable & Fibre Optic Cable Heat Release and Smoke Production Testing Equipment

Availability:

<p class="stock in-stock"></p>


EN 50399 Cable & Fibre Optic Cable Heat Release and Smoke Production Testing equipment uses imported German incandescent lamp as light source. We also use Oxygen analyzer which is imported from Germany SIEMENS.

(max file size 512 MB)

Specifications:-

Model Number:-D270

Power:-Electronic

Application:-Wire & Cable

Power supply:-220V 50Hz

Standard:-EN 50399

Warranty:-1 Year

Light source:-Imported German incandescent lamp

Oxygen analyzer:-Germany SIEMENS, paramagnetic

Nominal power:-10 W

(CO2) measuring instrument:-Infrared (IR) measurement

Ambient temperature:-5 °C ~ +45 °C

Specific parameters are as follows:

Light source: imported German incandescent lamp

Nominal power: 10W

Nominal voltage: 6V

Accuracy: ±0.01V

Receiver: For the Hamamatsu Silicon Photovoltaic Cell of Japan, the signal is amplified by the board and input to the computer through the I/O board. The spectral response is matched with the photometer of the International Commissioner of Light (CIE).

Laser system: The laser photometer should use a helium-neon laser with an output power of 0.5 maws to 2.0 maws. Air should be introduced into the tube, and the optics should maintain the cleanliness (F.4.2) that meets the requirements for light attenuation drift. Compressed air can be used instead of self-inhaled air.

 

Flue Gas Analysis Equipment:

  1. Oxygen analyzer: imported from Germany SIEMENS machine, paramagnetic.

1.1 Measurement range: (0-25)%

1.2 Signal output: 4-20mA;

1.3 Resolution 100×10-6

1.4 Relative humidity: <90% (no condensation);

1.5 Linearity deviation: <±0.1% O2;

1.6 Zero drift: ≤0.5%/month;

1.7 Range drift: ≤0.5%/month

1.8 The internal signal processing time is less than 1S;

1.9 Response time: T90<5 seconds

1.10 Repeatability: <±0.02% O2;

1.11 Local display: LCD display (with backlight)

1.12 Analog output: 4 to 20 mA 750 Ω

1.13 Ambient temperature: 5 °C ~ +45 °C; Power supply: 220VAC ± 10%, 50 ~ 60Hz.

1.14 The noise drift of the analyzer within 30min does not exceed 100 × 10-6; the resolution of the data acquisition output is better than 100 × 10-6;

 

  1. Carbon dioxide (CO2) measuring instrument:

2.1 Using infrared (IR) measurement, the sensor and board are imported from MBE, Germany;

2.2 Measurement range: 0-10%;

2.3 Repeatability: <±1%

2.4 Zero drift: ≤ 0.5% / month

2.5 Range drift: ≤ 0.5% / month

2.6 Linear deviation: <±1%

2.7 Response time: T90<3.5 seconds

2.8 The output resolution of the data acquisition system is better than 100×10-6

2.9 Analog output: 4~20mA 750Ω

2.10 Ambient temperature: 5 ° C ~ +45 ° C

2.11 Power supply: 220VAC±10%, 50~60Hz 5000W

2.12 The noise drift of the analyzer within 30 minutes does not exceed 100 × 10-6

 

  1. Analytical instrument pre-treatment: Before the analysis of the oxygen and carbon dioxide content of the flue gas generated during the test, pre-treatment is carried out to ensure the flue gas is dry and the particle concentration level required by the analytical instrument is reached. The pre-treatment consists of condensation, filters, German KNF sampling pumps, flow meters and piping.

 

Frequently Asked Questions:-

What is EN?

European Standards (EN) are documents that have been ratified by one of the 3 European Standards Organizations, CEN, CENELEC or ETSI. A standard represents a model specification, a technical solution against which a market can trade. It codifies best practices and is usually state of the art.

What does a fiber optic cable do?

A fiber optic cable is a network cable that contains strands of glass fibers inside an insulated casing. They’re designed for long-distance, high-performance data networking, and telecommunications. Compared to wired cables, fiber optic cables provide higher bandwidth and transmit data over longer distances.