Standard Compliance:
Fresh air is admitted by the high capacity blower, controlled by means of damper & measured using differential air velocity sensor for required 100-200 air changes per hour.
Model Number:-D195
Method 1:
Based on Flow Meter Measurement
The equipment is fitted with a Rota meter an external air source is arranged by the oven via flow meter fitted with needle valve control The customer to provide forced-air inside
Method 2:
Heat distortion assembly is affixed inside the aforesaid oven Air blow with air velocity tunnel equipped with differential air velocity measurement probe is connected to the oven. According to the standard? UL-1581 Reference standard
Deviceisused for measuring the deformation test of wire under a certain temperature and load
3 test stations suitable for various cable sizes.
Lower end diameter of pressure bar: 9.5? 0.2mm
Upper end diameter of pressure bar: ?19?0.2mm
Total weight of pressure bar: 250g
Multi-Station: 3
Frequently asked questions:-
What is a heat distortion test?