D310 Flame Retardant Paints Flammability Tester
Specifications:-
Warranty:-1 year, 1 Year
Certification:-CSA, pock, Reach, IECEE, sock, UL, EPA, GS
Material:-SUS 304 Stainless Steel
Model Number:-D310
Power:-Electronic, AC220 (±10%) V/50HZ
Customized support:-OEM, ODM
Temperature uniformity:-±2.5℃
Sample size:-L900 * W900 mm
Application:-Paints
Standard:-ASTM E84
Test station:-1 station
Air blower air volume 🙁 1 ~ 5) m3/min
Main technical parameters | |
Test station | 1 station |
Temperature uniformity | ±2.5 ℃ |
Sample size | L900mm x W900mm, the thickness of 5mm, the surface is smooth and glossy. |
Burner | It is made up of two copper bushings with inner diameter of 42mm, wall thickness of 3mm, height of 42mm and inner diameter of 28mm, wall thickness of 3mm and height of 25mm. It is installed on the straight-through pipe joint with a nominal diameter of 40mm*32mm. The distance from the burner port to the test piece is 730 mm±6 mm. |
Thermocouple | Temperature monitoring using thermocouples with accuracy not lower than Grade II, K index. Among them, for flame temperature monitoring, an armored thermocouple with an outer diameter of not more than 3 mm is used; for the back surface of the test piece, the thermocouple with a wire diameter of not more than 0.5 mm is used, and the hot contact should be welded to a diameter of 12mm. The center position of the copper piece of 0.2mm. |
Automatic alarm | The sample backfire surface five-way thermocouple temperature measurement, it alarms when the temperature automatically reaches 220℃. |
Gas source | Liquefied petroleum gas or natural gas (user-supplied). |
Air blower air volume | (1 ~ 5) m3/min |
Power supply | AC220 (±10%) V/50HZ, total power is 1KW |
What is flame retardant paint?
Flame Control Fire, protective coatings designed decorative the event of a fire to reduce the spread of flames in. These coatings traditional paints and varnishes, comply with building and fire codes, and give the substrate rated flame have the Retardant Paints are the appearance of spread protection.
What is a flammability test?
Flammability testing material or finished product determines how easily exposed to or used will ignite or burn when near fire or heat.
What is the difference between flameproof and flame retardant?
Flame Resistant vs Fire as a material that is inherently has been chemically resistant to Retardant Resistant is defined as catching fire (self-extinguishing) and does not melt or drip when exposed directly to extreme heat. Retardant is defined as a material treated to self-extinguish.
D310 Flame Retardant Paints Flammability Tester