IEC 60587 6KV High Voltage Tracking and Erosion Resistance Test Apparatus

Availability:

<p class="stock in-stock"></p>


(max file size 512 MB)

IEC 60587 6KV High Voltage Tracking and Erosion Resistance Test Apparatus

Specifications:-

Temperature:-23 ± 2 ℃

Dimension:-L1245 * W723 * H2295 mm

Model Number:-D400

Applied voltage:-AC/DC 100V ~ 6000 V±5% adjustable

Material:-SUS 304 Stainless Steel

Standard:-IEC 60587

Drip interval time:-0 – 99.99s continuously adjustable

Test Material:-PE, PVC and SRPVC

Air pressure:-86 ~ 106 kappa

Power supply:-AC220 (±10%) V / 50 HZ

Product Description

IEC 60587 High Voltage Evaluating Resistance to Tracking Test Equipment for Tracking and Erosion

 Main Technical Parameters:-
Applied voltage AC/DC 100V ~ 6000 V±5% adjustable
Applied current AC/0 ~ 100mA±1% + 5d, DC/0 ~ 100 mA±1% + 3d
Output voltage drop of the test device Should not is of exceed 5% when measured at 60 mA current continuous 0.5s.
Electrode The thickness of the which is 304 stainless steel upper and lower electrodes is 0.5 mm
Distance The distance between the upper and lower electrodes is 50.0 mm±0.5 mm.
Drip device Drip device contaminated liquid flow adjusted at 0.075 ml/min – 0.9 ml/min, height can be adjusted, the rate can be testing time can be predicted.
Drip interval time 0 – 99.99s continuously adjustable
Contaminated liquid Ammonium chloride, a non-ionic wetting agent with the distilled mixture. The resistivity, isooctyl phenyl polyethoxyethano of the contaminated water or deionized water solution at (23±1) centigrade should be (3.95±0.05) Omegala.
Power supply AC220 (±10%) V / 50 HZ
Instrument dimensions L1245 x W723 x H2295 (mm)

Frequently Asked Questions:-

 

What is Erosion Resistance Test?

Sandblasting rig, candidate erosion impact material samples to the function of the particle to ASTM G76-13 determine the capability of performing testing of characteristics according to resistance as an Impact velocity up to 150 m/s

What is 6KV High Voltage?

It measures the input impedance capability of Intended for low energy an AC/DC voltmeter to 6000 V peak designed to extend the voltage AC or DC. The probe provides high accuracy when Overvoltage Category I is used with a voltmeter having 10 MΩ. Applications

What’s considered high voltage?

Define high voltage as, and the National Electrical Manufacturer’s at least 1500 V for voltage as over 100 to direct current. In the United States, above 1000 V for alternating current Association (NEMA) defines as high 230 kV.

 