D316 Thermal Acoustic Insulation Materials Flame Spread Flammability Tester is used to evaluate flame spread characteristics and flammability of thermal insulation and sound insulation materials.
Specifications:-
Warranty:- 1 year
Certification:-CSA, pock, Reach, IECEE, sock, UL, EPA, GS
Size of the fixing frame:-L584 x W333 mm
Built-in chimney:-L423 x W139 x H330 mm
Radiant panel test chamber:-L1397 x W495 mm
Material:-SUS 304 Stainless Steel
Model Number:-D316
Power:-Electronic
Application:-Thermal/Acoustic Insulation Materials
Standard:-14 CFR 91.613, 14 CFR 121.312, 14 CFR 125.113, and 14 CFR 135.170
Max Temperature:-816 ℃
Heat flow meter 🙁 0 ~ 57) kW / mm2
Detailed Specifications | |
Burner | The burner is an axisymmetric venturi ignition device with a propane supply pipe with an aperture of 0.15mm. The length of combustion tube is 71mm. |
Thermocouple | K-type thermocouple |
Heat flow meter | 25.4mm cylindrical water-cooled, total heat flux type, box type gardon heat flow meter, with a range of (0-57) kW/mm2. |
Heat flow meter bracket | Made of stainless steel plate, with the length of (333 ± 3) mm (front to back) and width (2.3 ± 3) mm. |
Data acquisition and processing | The computer data acquisition system is used to measure and record the output value of heat flow meter and thermocouple. During calibration, the data acquisition system records the output value of the heat flow meter at least once every second. |
Timer | The timing device for measuring the action time of burner flame is computer software timing, and its accuracy shall be ± 1 s/h. |
Gas source | Propane (provided by the user) |
Control box size | L650 x W590 x H2200 mm |
Size of test chamber | L1510 x W850 x H2300 mm |
Working power supply | AC380V, 50Hz |
Total power | 14 KW |